6632--Tissue Processors for VISN 22
SOL #: 36C26226Q0639Combined Synopsis/Solicitation
Overview
Buyer
Veterans Affairs
Veterans Affairs, Department Of
262-NETWORK CONTRACT OFFICE 22 (36C262)
Gilbert, AZ, 85297, United States
Place of Performance
Place of performance not available
NAICS
Analytical Laboratory Instrument Manufacturing (334516)
PSC
Analysis Instruments, Medical Laboratory Use (6632)
Set Aside
No set aside specified
Original Source
Timeline
1
Posted
Apr 16, 2026
2
Submission Deadline
May 4, 2026, 2:00 PM
Qualification Details
Fit reasons
- NAICS alignment with historical contract wins in similar service areas.
- Scope strongly matches core technical capabilities and delivery model.
Risks
- Past performance thresholds may require one additional teaming partner.
- Potential clarification needed on staffing minimums before bid/no-bid.
Next steps
Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.
Quick Summary
The Department of Veterans Affairs (VA), Network Contracting Office 22, has issued a Combined Synopsis/Solicitation (RFQ) for Tissue Processors and Uninterrupted Power Supplies (UPS) for Histology Departments across various VISN 22 facilities. This unrestricted, open-market opportunity seeks to procure equipment for processing tissue specimens. Proposals are due May 04, 2026, at 07:00 AM PDT.
Scope of Work
The solicitation requires the procurement of 11 Tissue Processors and 11 UPS units. Key requirements for the Tissue Processors include:
- Must be the newest model, a standard product of the manufacturer (refurbished not accepted).
- Instrument software for performance monitoring and operator notification of failures.
- Ability to manage reagent rotation and use non-proprietary reagents.
- Capacity for a total of 600 cassettes (minimum 300 per run).
- Automated reagent reconstitution, solution transfer, and temperature-controlled retort.
- Xylene-free processing capability and a filtering system for noxious fumes.
- Power requirement: Single phase, 115 VAC ± 10%, 50/60 Hz, 12 A, with at least 4 level sensors. Each UPS must provide a minimum of 20 minutes of power after failure, include an audible alarm, and have at least 4 power outlets. All necessary accessories and comprehensive documentation (manuals, environmental/utility requirements) must be provided. The contractor is also responsible for an implementation plan for installation (within 90 days ARO) and training for at least two operators per facility.
Contract Details
- Contract Type: Firm-Fixed-Price.
- Period of Performance: Delivery and installation within 90 Days After Receipt of Order (ARO).
- Set-Aside: Unrestricted, open-market solicitation.
- Product Service Code: 6632 (Analysis Instruments, Medical Laboratory Use).
Submission & Evaluation
- Proposal Submission: Due by May 04, 2026, 07:00 AM PDT. Submissions must be sent via email to Marcos.Diaz@va.gov in Adobe or Microsoft Word format.
- Questions Due: April 22, 2026, 07:00 AM PST, via email to Marcos.Diaz@va.gov.
- Evaluation: Award will be made to the responsible offeror with the lowest-priced offer that meets all requirements. Price is the sole evaluation factor.
- Eligibility: Offerors must provide evidence of laboratory licensing, accreditation, and issuance by the College of American Pathologists (CAP).
Additional Notes
This is a brand name or equal procurement.