7312023 Installer Cooler with Bottle Filler, Building 8102

SOL #: N400857312023Solicitation

Overview

Buyer

Dept Of Defense
Dept Of The Navy
NAVFACSYSCOM MID-ATLANTIC
NORFOLK, VA, 23511-0395, United States

Place of Performance

Cherry Point, NC

NAICS

Electrical Contractors and Other Wiring Installation Contractors (238210)

PSC

Repair Or Alteration Of Miscellaneous Buildings (Z2JZ)

Set Aside

8(a) Sole Source (FAR 19.8) (8AN)

Timeline

1
Posted
Apr 29, 2026
2
Submission Deadline
May 22, 2026, 4:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of the Navy (NAVFACSYSCOM MID-ATLANTIC) is issuing a Solicitation for the installation of a bi-level water cooler with a bottle filler at Building 8102, MCAS Cherry Point, NC. This is an 8(a) Sole Source (FAR 19.8) opportunity specifically for N4008524D0066 Driven Contractors, LLC. to meet NAVFAC's business standards for local disadvantaged and small 8(a) businesses. Responses are due by May 22, 2026.

Scope of Work

The objective is to provide and install a bi-level water cooler with a bottle filling dispenser, including the necessary electrical circuit and receptacle, at Building 8102, MCAS Cherry Point. Key tasks include:

  • Installing a new 1-pole, 20-amp circuit breaker in existing Panel M and a surface-mounted 120V duplex outlet.
  • Running size #12 THHN copper wire in EMT from Panel M to the new receptacle.
  • Providing and installing a bi-level water fountain above an existing wall clean out.
  • Connecting the new water fountain to existing domestic cold water and sewer lines.
  • The water fountain must meet specific standards: ICC A117.1, ANSI/ASHRAE 18, UL 399, NSF/ANSI/CAN 61, and have an 8 gph minimum capacity. Bubbler spouts must be mounted between 38 and 43 inches above the floor and direct water flow at least 4 inches above the unit basin.

Contract & Timeline

  • Contract Type: Solicitation
  • Set-Aside: 8(a) Sole Source (FAR 19.8) for N4008524D0066 Driven Contractors, LLC.
  • Response Due: May 22, 2026, 4:00 PM UTC
  • Published Date: April 29, 2026, 3:29 PM UTC
  • Product Service Code: Z2JZ (Repair Or Alteration Of Miscellaneous Buildings)

Performance Standards & Place of Performance

  • Location: Building 8102, MCAS Cherry Point (Boque Field), North Carolina. The building will remain occupied during construction.
  • Standards: Work must comply with manufacturer instructions and referenced NAVFAC drawings. The contractor must minimize interference with normal building operations.
  • Notices: Permission to interrupt activity roads, railroads, or utility services requires a minimum of 15 calendar days written notice.

Special Requirements

  • Personnel: Contractor personnel must comply with activity regulations (safety, fire, traffic, security).
  • Base Access: Access to MCAS Cherry Point requires adherence to DBIDS or obtaining One-Day Passes, involving background checks and identification verification.
  • Insurance: Minimum insurance coverage is required per FAR 28.307-2 Liability.
  • Key Personnel: The project requires a Superintendent, Quality Control Manager, and Site Safety and Health Officer.
  • Outages: Planned outages and service disruptions require contractor written requests 15 days in advance and a contingency plan.
  • PPE: Detailed personal protective equipment (PPE) requirements include hearing protection, safety glasses, hard hats, and safety shoes.
  • Closeout: Closeout submittals include Spare Parts Data, a Warranty Management Plan, and Operation & Maintenance Manuals.