Timeline
Qualification Details
Fit reasons
- NAICS alignment with historical contract wins in similar service areas.
- Scope strongly matches core technical capabilities and delivery model.
Risks
- Past performance thresholds may require one additional teaming partner.
- Potential clarification needed on staffing minimums before bid/no-bid.
Next steps
Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.
Quick Summary
The Department of the Air Force, on behalf of the US Space Force, is conducting a Sources Sought for market research to identify capable vendors for the Buckley SFB Rectifier Inverter System Replacement in Aurora, CO. This is a Total Small Business Set-Aside. Responses are due by April 2, 2026.
Purpose
This Sources Sought aims to gather information from industry to identify qualified vendors and obtain feedback for the complete replacement of the rectifier/inverter system at the US Space Force Buckley Space Force Base DISA node facility (Building 730, Room 132). The existing system sustained significant damage due to a major water main break.
Scope of Work
The requirement is for the full replacement of the existing rectifier/inverter/power distribution system. This includes new battery strings, battery disconnects, and A/C power circuits. The system provides stable, reliable power for DoD long-haul communications by converting commercial, generator, and uninterruptable power supplies to direct current (DC).
Key Requirements include:
- A complete replacement system meeting or exceeding 2,800 amps (200 amps x 14 units).
- Batteries equivalent to or better than C&D Technologies MS Endur II (3 strings with 48 jars per string).
- Battery disconnects equivalent to or better than Peco II, -48v 1800 amp units.
- New power distribution to the DC breaker panel (loads A, B, C, D) from commercial, battery, and generator sources, meeting or exceeding Lorain Power System Model 1231v1.
- Power must feed into sectors A, B, C, D, E, and F of the DC breaker panel.
- The inverter system must accommodate existing DC breaker panels and A/C circuits.
Information Requested from Vendors
Respondents are asked to provide:
- Company Information: Name, address, CAGE, UEI, contact person, business size, and socioeconomic categories.
- Statement of Need Feedback: Identify unclear specifications, missing critical components, or recommendations for improvement.
- Technical Capability: Describe expertise, equipment, resources for the full replacement, general approach to designing/integrating a power rectification and distribution system, and installation methodology (minimizing disruption).
- Past Performance: Examples of similar projects within the last 5 years, especially for DoD or federal agencies.
- Delivery/Installation: Estimated lead time for equipment delivery and installation timeline.
- Price Estimate: A Rough Order of Magnitude (ROM) price for the complete solution.
Contract & Timeline
- Type: Sources Sought (Market Research)
- Set-Aside: Total Small Business
- Response Due: April 2, 2026, 2:00 PM UTC
- Published Date: March 25, 2026
Place of Performance
Buckley Space Force Base, Aurora, CO, United States.