HAWAII COMPUTER ROOM AIR HANDLING REPLACEMENT
Overview
Buyer
Place of Performance
NAICS
PSC
Set Aside
Original Source
Timeline
Qualification Details
Fit reasons
- NAICS alignment with historical contract wins in similar service areas.
- Scope strongly matches core technical capabilities and delivery model.
Risks
- Past performance thresholds may require one additional teaming partner.
- Potential clarification needed on staffing minimums before bid/no-bid.
Next steps
Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.
Quick Summary
The Defense Information Systems Agency (DISA) is soliciting proposals for the replacement of two Computer Room Air Handling (CRAH) units and the addition of aisle containment in Computer Room 191 at Data Center Hawaii, Pearl Harbor, HI. This is a Total Small Business Set-Aside. Proposals are due April 1, 2026, at 10:00 AM CST.
Scope of Work
This project involves the comprehensive replacement of end-of-life CRAH units that no longer provide adequate cooling. Key tasks include:
- Project Management: Developing schedules, conducting meetings, submitting shop drawings, and investigating existing conditions.
- CRAH Unit Replacement: Removing existing units, procuring and installing new CRAH units (minimum 140 kW cooling capacity, 10 tons nominal), ensuring continuous operation during replacement, and connecting to the Building Automation System (BAS).
- Electrical Work: Reusing or upgrading electrical cable and conduit, ensuring compliance with electrical codes and safety programs. Splicing on existing feeders is not allowed.
- Aisle Containment: Procuring and installing end-of-aisle doors, rack gap panels, and brushed rack blanking panels.
- Project Close-Out: Providing warranties, final as-built drawings, training for O&M staff, and submitting O&M binders. The period of performance is 12 months upon award.
Contract & Timeline
- Contract Type: Firm-Fixed-Price
- Set-Aside: Total Small Business
- Product Service Code: 4120 (Air Conditioning Equipment)
- Place of Performance: Data Center Hawaii, 477 Essex St Ste 180 (Building 77), Pearl Harbor, HI 96860-5815.
- Proposal Due Date: April 1, 2026, at 10:00 AM CST (15:00:00Z)
- Published Date: February 18, 2026 (Initial Solicitation), with latest amendment on March 24, 2026.
Evaluation & Submission
Award will be made to the responsible offeror whose proposal represents the overall best value using a Lowest Price Technically Acceptable (LPTA) process. Evaluation factors include Technical/Management (rated Acceptable/Unacceptable) and Price. Proposals must be submitted electronically in separate files for each volume (Executive Summary, Technical/Management, Price, Past Performance, Contract Documentation). Offerors must hold prices firm for 60 calendar days.
Key Requirements & Notes
- Mandatory Site Visit: A pre-proposal site visit was held on February 25, 2026. Questions from the site visit were addressed via amendment.
- Technical Specifications: Detailed specifications for CRAH units (Appendix D), electrical safety (Appendix C), and labeling standards (Appendix B) are provided. Bidders must adhere to these.
- Quality Assurance: A Quality Assurance Surveillance Plan (QASP) outlines government monitoring, performance standards (100% AQL for IT rack cooling), and rating systems.
- Wage Determination: Bidders must account for minimum wage rates and fringe benefits as per the Service Contract Act.
- Non-Disclosure Agreement (NDA): Contractor personnel will be required to sign a DISA NDA.
Contact: Eric Mead (eric.L.mead2.civ@mail.mil)