INSTALL BACK UP GENERATOR AND ATS FOR NMCI ROOM, BLDG 127, DAM NECK ANNEX

SOL #: N4008525R0072Solicitation

Overview

Buyer

Dept Of Defense
Dept Of The Navy
NAVFACSYSCOM MID-ATLANTIC
NORFOLK, VA, 23511-0395, United States

Place of Performance

Virginia Beach, VA

NAICS

Commercial and Institutional Building Construction (236220)

PSC

Repair Or Alteration Of Miscellaneous Buildings (Z2JZ)

Set Aside

Total Small Business Set-Aside (FAR 19.5) (SBA)

Timeline

1
Posted
Mar 17, 2026
2
Last Updated
Mar 18, 2026
3
Submission Deadline
Mar 26, 2026, 6:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of the Navy, NAVFACSYSCOM MID-ATLANTIC, is soliciting proposals for the installation of a backup generator and Automatic Transfer Switch (ATS) for the NMCI equipment room in Building 127 at Dam Neck Annex, Virginia Beach, VA. This project, identified as a Solicitation, is a Total Small Business Set-Aside (FAR 19.5), specifically restricted to 8(a) Multiple Award Construction Contract (MACC) holders. Proposals are due by March 26, 2026, at 2:00 PM EDT.

Scope of Work

The project aims to provide backup power to the NMCI equipment room's IT server racks and HVAC system in Room S145 of Building 127, Taylor Hall. Key deliverables include:

  • Installation of a diesel stand-by generator and ATS.
  • Installation of a Computer Room Air Conditioning (CRAC) unit to cool the NMCI equipment room, powered by the backup system.
  • Interior improvements, including the addition of double doors for the NMCI server room.
  • Demolition of existing electrical disconnect equipment and LC-2 panelboard, with circuits migrated to a new 225A MLO panelboard.
  • Compliance with applicable codes, standards (e.g., UFC, IBC, NFPA, ASHRAE), and environmental requirements.
  • A load bank test is required upon completion of generator and ATS installation.
  • The project requires the use of brand-name commercial Facility Related Control Systems (FRCS) programmable building controllers from Johnson Controls International (Metasys) or Automated Logic Corporation (WebCTRL) for interoperability and cybersecurity.

Contract Details

  • Contract Type: Design-Build Task Order under an existing 8(a) MACC contract.
  • Estimated Value: $500,000 - $1,000,000.
  • Period of Performance: 420 calendar days from task order award.
  • Liquidated Damages: $189.14 per calendar day of delay.
  • Bonds: Performance and Payment Bonds are required within 10 calendar days of award. A Bid Guarantee (20% of offer price or $3,000,000, whichever is less) is also required.

Set-Aside & Eligibility

This is an 8(a) Set-Aside for facilities within the NAVFAC Midlant Hampton Roads Area of Responsibility. Only listed 8(a) MACC contract holders are eligible to submit proposals.

Submission & Evaluation

  • Proposal Due Date: March 26, 2026, at 2:00 PM EDT.
  • Evaluation Criteria: Proposals will be evaluated on PRICE ONLY, with the award made to the responsible offeror with the LOWEST PRICE.
  • Pre-Proposal Inquiries (PPIs): The cut-off date for PPIs was August 12, 2025, and responses have been issued.
  • Site Visit: A site visit was held on August 6, 2025.
  • Required Forms: Bidders must use the updated Attachment G (Price Schedule Form) and consider the updated Wage Determination (VA2260167 dated 1/30/2026).

Key Documents & Notes

  • Amendments: Multiple amendments have been issued, with the latest (Amendment 0005) extending the proposal due date. Offerors must acknowledge all amendments.
  • Base Access: Specific procedures and forms are required for base access to NAS Oceana and Dam Neck Annex.
  • Operational Constraints: Building 127 must remain operational throughout construction, requiring sequenced work and approved utility outages during off-hours.
  • FAR 52.204-24: Offerors must comply with requirements regarding covered telecommunications equipment or services.

People

Points of Contact

Files

Files

Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download

Versions

Version 2Viewing
Solicitation
Posted: Mar 18, 2026
Version 1
Solicitation
Posted: Mar 17, 2026
View
INSTALL BACK UP GENERATOR AND ATS FOR NMCI ROOM, BLDG 127, DAM NECK ANNEX | GovScope