N041--Ambulance HVAC System With Installation

SOL #: 36C26226Q0525Combined Synopsis/Solicitation

Overview

Buyer

Veterans Affairs
Veterans Affairs, Department Of
262-NETWORK CONTRACT OFFICE 22 (36C262)
Gilbert, AZ, 85297, United States

Place of Performance

Prescott, Arizona

NAICS

All Other Automotive Repair and Maintenance (811198)

PSC

Installation Of Equipment: Refrigeration, Air Conditioning, And Air Circulating Equipment (N041)

Set Aside

Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) (SDVOSBC)

Timeline

1
Posted
Mar 18, 2026
2
Last Updated
Apr 2, 2026
3
Submission Deadline
Apr 8, 2026, 6:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of Veterans Affairs (VA), Network Contracting Office 22, has issued a Combined Synopsis/Solicitation for the Ambulance HVAC System With Installation at the Northern Arizona VA Medical Center in Prescott, AZ. This opportunity seeks a contractor to provide and install two rooftop HVAC systems on ambulances to protect temperature-sensitive medical equipment. Offers are due by April 8, 2026, 11:00 AM PDT.

Scope of Work

The project requires the provision and installation of two rooftop HVAC systems on ambulances. Key requirements include:

  • Installation of systems equivalent to a Furrion Chill FACR13SA with installed Heat Strip.
  • Systems must operate on 115V/30amp AC shore power.
  • Must feature a dual-fan design for increased airflow and cooling efficiency.
  • Integrated temperature control capability is essential.
  • Installation must be performed by a local certified vendor familiar with rooftop HVAC vehicle modification.
  • Systems must meet RVIA and ANSI A119.2 standards and comply with DOE and EPA energy efficiency requirements.
  • A minimum capacity of 13,500 BTU is required.
  • The purpose is to maintain controlled interior temperatures when ambulances are parked and plugged into shore power.

Contract Details

  • Contract Type: Firm-Fixed-Price.
  • Product Service Code: N041 (Installation Of Equipment: Refrigeration, Air Conditioning, And Air Circulating Equipment).
  • NAICS Code: 811198 (All Other Automotive Repair and Maintenance), with a size standard of $10 Million.
  • Set-Aside: This acquisition is UNRESTRICTED.
  • Place of Performance: Northern Arizona VA Medical Center, 500 N. State Highway 89, Prescott, Arizona 85723.

Submission & Evaluation

  • Offer Due Date: April 8, 2026, 11:00 AM PDT.
  • Questions Due: April 3, 2026, 11:00 AM Pacific time.
  • Submission: Offers must be submitted electronically, include a cover letter, and be organized into two separate files as specified in the solicitation.
  • Evaluation: Award will be based on the lowest-priced offer that meets all requirements, is reasonable, and comes from a responsible offeror. The Government anticipates adequate price competition and may award without discussions.
  • Special Standard of Responsibility: The contractor must be located within 20 miles of the NAVAHCS VA facility in Prescott, AZ.
  • Past Performance: Will be evaluated, with a neutral rating if no information is found.

Important Notes

Offerors must be registered in the VA's financial system (using the 10091 webform) and the System for Award Management (SAM). The solicitation includes numerous FAR and VAAR clauses.

People

Points of Contact

David OdneContracting OfficerPRIMARY

Files

Files

Download
Download
Download

Versions

Version 2Viewing
Combined Synopsis/Solicitation
Posted: Apr 2, 2026
Version 1
Sources Sought
Posted: Mar 18, 2026
View
N041--Ambulance HVAC System With Installation | GovScope