Repair and Calibration of Rohde & Schwarz Spectrum Analyzers

SOL #: PZZG0415Sources Sought

Overview

Buyer

DEPT OF DEFENSE
Dept Of The Air Force
FA9302 AFTC PZZ
EDWARDS AFB, CA, 93524-1185, United States

Place of Performance

Edwards, CA

NAICS

Electronic and Precision Equipment Repair and Maintenance (811210)

PSC

Maintenance, Repair And Rebuilding Of Equipment: Instruments And Laboratory Equipment (J066)

Set Aside

No set aside specified

Timeline

1
Posted
Apr 15, 2026
2
Response Deadline
Apr 20, 2026, 7:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The United States Air Force is conducting a Sources Sought market survey to identify potential sources for depot-level repair and calibration services for three non-operational Rohde & Schwarz FSV40-N Signal and Spectrum Analyzers. This is for market research purposes only; it is not a solicitation for proposals. Responses are due April 20, 2026.

Scope of Work

The contractor will be required to provide all necessary labor, parts, materials, facilities, and transportation to perform depot-level repair, adjustment, modification, and calibration. The objective is to restore each unit to a like-new, fully functional condition meeting all original equipment manufacturer (OEM) specifications, with a comprehensive warranty. Key tasks include:

  • Evaluation and Repair: Conduct full diagnostic evaluation and perform "Standard Price Repair" to restore functionality, including component replacement.
  • System Updates: Implement all mandatory preventive maintenance procedures and reliability modifications specified by Rohde & Schwarz.
  • Calibration and Verification: Perform full calibration in an ISO 9001-certified facility, compliant with IEC/ISO 17025 standards and ILAC-G8 guard-banding. Documented test results demonstrating OEM performance parameters are required.

Information Requested

Interested offerors capable of fully supporting this requirement should furnish:

  • Company name, SAM UEI, CAGE Code, address, points of contact, phone, and email.
  • Brief description of experience in providing specified services.
  • Identification of business size (small or large) and socioeconomic disadvantaged category, as listed in SAM. The potential NAICS code is 811210 "Electronic and Precision Equipment Repair and Maintenance" with a Small Business Size Standard of $34,000,000.
  • Any other useful information, limited to no more than 3 pages.

Contract & Timeline

  • Type: Sources Sought / Market Survey
  • Set-Aside: None specified (seeking business size information)
  • Response Due: April 20, 2026, at 12:00 PM Pacific Daylight Time
  • Published: April 15, 2026
  • Place of Performance: Edwards, CA 93524

Additional Notes

This is for information only; no contract will be awarded from this synopsis, and no reimbursement will be made for response costs. The Air Force will not provide feedback or clarification. Only responses demonstrating full support for all areas will be accepted; partial support responses will not be considered.

People

Points of Contact

Carmen BarahonaPRIMARY

Files

Files

No files attached to this opportunity

Versions

Version 1Viewing
Sources Sought
Posted: Apr 15, 2026
Repair and Calibration of Rohde & Schwarz Spectrum Analyzers | GovScope