Rubidium Generator(Sr-82/Rb-82) with Associated Accessories
Overview
Buyer
Place of Performance
NAICS
PSC
Set Aside
Original Source
Timeline
Qualification Details
Fit reasons
- NAICS alignment with historical contract wins in similar service areas.
- Scope strongly matches core technical capabilities and delivery model.
Risks
- Past performance thresholds may require one additional teaming partner.
- Potential clarification needed on staffing minimums before bid/no-bid.
Next steps
Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.
Quick Summary
The Department of the Army's Medical Readiness Contracting Officer-W (MRCO-W), on behalf of William Beaumont Army Medical Center (WBAMC), is issuing a Sources Sought Notice to identify potential sources for a Rubidium Generator (Sr-82/Rb-82) with Associated Accessories for cardiac positron emission tomography (PET) imaging at Fort Bliss, TX. This is for market research and planning purposes only. Responses are due May 6, 2026.
Scope of Work
WBAMC seeks a complete, integrated, FDA-approved Sr/Rb generator system and accessories capable of producing Rb chloride injections for PET myocardial perfusion imaging. The system must be 100% compatible with the current Bracco Diagnostics CardioGen-82® Infusion System (Model 1701) to ensure continuous cardiac PET imaging service. Key requirements include:
- System: Generator column, self-contained, shielded cart.
- Performance: Enable rapid, on-demand serial rest/stress studies (30-35 minutes) and support 10-15+ patient studies per day.
- Isotope Production: Utilize Strontium-82 to produce Rubidium-82.
- Safety: Meet FDA-approved specifications for breakthrough levels (ALARA principles).
- Software: Include proprietary software for imaging, data management, and automated Quality Control.
- Accessories: Infusion sets, patient administration sets, waste containers, vented caps, printer paper, and an accessory pack.
- Generator Life: Functional lifespan of 4 to 12 weeks, requiring regular replacement/reloading.
- Support: 24/7 technical support for malfunctions or breakthrough alerts.
Contract & Timeline
- Type: Sources Sought / Market Research
- Set-Aside: None specified
- Response Due: May 6, 2026, at 2:00 PM Z
- Published: April 24, 2026
Evaluation
Responses will inform the Government's acquisition strategy. Insufficient information to verify competition may lead to a sole-source contract. This notice is not a solicitation, and not responding does not preclude participation in future RFQs.
Submission Requirements
Interested parties should provide:
- Company name, UEI, CAGE code, point of contact, and socio-economic category(ies) related to NAICS 325412.
- Capability Statement (limited to 10 pages) detailing how requirements are met, including product literature and current installations.
- Demonstrated experience supplying Sr-82/Rb-82 generators to similar medical facilities.
- Proof of FDA approval for the generator system.
- Confirmation of compatibility with Bracco CardioGen-82 Infusion Systems.
- Description of shipping, tracking, and technical support capabilities.