STA Morro Bay fire alarm and fire suppression system mods

SOL #: 30471PR260000004Combined Synopsis/Solicitation

Overview

Buyer

Homeland Security
Us Coast Guard
BASE LOS ANGELES/LONG BEACH(00037)
SAN PEDRO, CA, 90731, United States

Place of Performance

Morro Bay, CA

NAICS

Fire Protection (92216)

PSC

Modification Of Equipment: Fire Control Equipment (K012)

Set Aside

Historically Underutilized Business (HUBZone) Set-Aside (FAR 19.13) (HZC)

Timeline

1
Posted
Jun 10, 2026
2
Submission Deadline
Jun 24, 2026, 10:15 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The United States Coast Guard (USCG) Base Los Angeles-Long Beach (LA-LB) Procurement Office is soliciting bids for modifications to the fire alarm and fire suppression systems at USCG Station Morro Bay, CA. This acquisition is a 100% set-aside for certified HUBZone small business concerns. Bids are due by June 24, 2026, at 10:15 PM PST.

Scope of Work

The Statement of Work (SOW) details the following objectives:

  • Relocate two smoke detector heads from inside bathrooms and potentially remove them if non-essential.
  • Relocate or install new smoke detectors in the kitchen area.
  • Relocate or remove two fire suppression sprinkler heads from areas at risk of accidental activation.

The contractor must provide all necessary labor, materials, services, tools, equipment, and supervision, ensuring compliance with applicable codes, standards, and regulations, including NFPA 72 (smoke detectors) and NFPA 13 (sprinkler systems), OSHA, and FAR 52.236-7. Post-installation testing, reprogramming, and updated documentation (as-built drawings, certification) are required.

Contract & Timeline

  • Contract Type: Combined Synopsis/Solicitation
  • Set-Aside: Historically Underutilized Business (HUBZone) Set-Aside (FAR 19.13)
  • Product Service Code: K012 - Modification Of Equipment: Fire Control Equipment
  • Response Date: June 24, 2026, 10:15 PM PST
  • Published Date: June 10, 2026, 12:10 PM PST
  • Place of Performance: USCG Station Morro Bay, 1279 Embarcadero, Morro Bay, CA 93442. Work hours are Monday-Friday, 08:00 am to 16:00 pm.

Evaluation Factors

Award will be made to the responsible offeror whose proposal is most advantageous to the Government, considering price and past performance. The Government will evaluate offers for award purposes by adding the total price for all options to the total price for the basic requirement, per FAR 52.212-2.

Additional Notes

  • Site visits will be coordinated by personnel at Station Morro Bay.
  • Bids should be emailed to the Primary POC listed in the solicitation.
  • Contractor Requirements: Provide a Contract Manager, ensure employees are identifiable and do not pose a threat or have conflicts of interest. Proper identification is required for all contractor employees on USCG facilities. A site visit and verification are required before work commencement. Mobilization/demobilization plans, adherence to FAR 52.236-12 (Cleaning Up), and verification for hazardous materials are also required. Contractors must secure all necessary permits and minimize disruptions to other systems. A cost breakdown for labor, materials, and equipment is required (FAR 15.408 Table 15-2), and adherence to FAR Part 19 for subcontractor selection is expected.
  • Primary Contact: Frank Rodriguez, Frank.L.Rodriguez1@USCG.mil, 510-612-3694.

People

Points of Contact

Files

Files

Download

Versions

Version 1Viewing
Combined Synopsis/Solicitation
Posted: Jun 10, 2026
STA Morro Bay fire alarm and fire suppression system mods | GovScope