Transcranial Magnetic Stimulator (TMS) Pro R30 Magnetic Stimulator with embedded Express TMS, accessories and supportive TMS Navigator TS Plus Package with Lyra Edition.

SOL #: PANHCA-26-P-0000-09862Sources Sought

Overview

Buyer

DEPT OF DEFENSE
Dept Of The Army
W40M MRC0 WEST
JBSA FT SAM HOUSTON, TX, 78234-4504, United States

Place of Performance

DWG, TX

NAICS

No NAICS code specified

PSC

No PSC code specified

Set Aside

No set aside specified

Timeline

1
Posted
May 8, 2026
2
Response Deadline
May 14, 2026, 3:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Medical Readiness Contracting Office - W, Fort Sam Houston, Texas, is conducting market research (Sources Sought) to identify potential sources for a MagVenture Transcranial Magnetic Stimulator (TMS) Pro R30 Magnetic Stimulator system for Brooke Army Medical Center (BAMC) on Fort Sam Houston, TX. This effort aims to determine if a competitive acquisition or a total Small Business Set-Aside is feasible. Responses are due May 14, 2026.

Scope of Work

The requirement is for one (1) Model R30 MagVenture Transcranial Magnetic Stimulator (TMS) Pro R30 Magnetic Stimulator with embedded Express TMS, accessories, and a supportive TMS Navigator TS Plus Package with Lyra Edition. This system, FDA cleared for Major Depression Disorder (MDD) and Obsessive-Compulsive Disorder (OCD), will replace an obsolete Neurostar TMS machine. Key salient characteristics include:

  • Compatibility with over 8 FDA-cleared transducer coils for various indications.
  • Ability to capture and record the rate of change of current flow (di/dt).
  • Liquid-cooled transducer coils enabling uninterrupted patient treatment (5000+ pulses at 75% output).
  • Clicking sounds below OSHA's 90dB SPL threshold.
  • Compatibility and two-way communication with FDA-cleared Localite TMS Navigator neuro-navigation systems.
  • No monthly subscription fees.
  • Specific footprint, chair weight/capacity, and recommended room size.

Contract & Timeline

  • Type: Sources Sought / Market Research
  • NAICS: 334510 (Surgical Appliance and Supplies Manufacturing, 1250 employees)
  • Set-Aside: Market research to determine potential for a total Small Business Set-Aside (including 8(a), SDVOSB, HubZone, WOSB).
  • Response Due: May 14, 2026, 10:00 AM CST
  • Published: May 8, 2026
  • Anticipated RFP Posting: May 28, 2026

Evaluation

Responses will assist the Government in determining the best acquisition strategy and whether responsible sources exist for this procurement. This is for planning purposes only and does not constitute a commitment to issue a solicitation or award a contract.

Additional Notes

Interested parties should email responses to geraldine.i.hernandez.civ@health.mil by the due date. Responses must include business size (NAICS 334510) and socio-economic category, company details (DUNS, CAGE, contact info), and confirmation of interest and capability.

People

Points of Contact

Gerri Hernandez (Contract Specialist)PRIMARY

Files

Files

No files attached to this opportunity

Versions

Version 1Viewing
Sources Sought
Posted: May 8, 2026
Transcranial Magnetic Stimulator (TMS) Pro R30 Magnetic Stimulator with embedded Express TMS, accessories and supportive TMS Navigator TS Plus Package with Lyra Edition. | GovScope