Y1DA--CON NRM 668-22-105 Upgrade AHU-09/15 Mechanical Systems FY26 Tier 1
Overview
Buyer
Place of Performance
NAICS
PSC
Set Aside
Original Source
Timeline
Qualification Details
Fit reasons
- NAICS alignment with historical contract wins in similar service areas.
- Scope strongly matches core technical capabilities and delivery model.
Risks
- Past performance thresholds may require one additional teaming partner.
- Potential clarification needed on staffing minimums before bid/no-bid.
Next steps
Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.
Quick Summary
The Department of Veterans Affairs (VA) has cancelled Solicitation 36C26026R0004 for the Upgrade of AHU-09/15 Mechanical Systems at the Mann-Grandstaff VA Medical Center in Spokane, WA, without award. This cancellation was announced via Amendment 0005 on March 18, 2026.
Opportunity Background
This solicitation, initially issued as a 100% Small Business set-aside, sought a contractor for a Firm-Fixed-Price contract to upgrade Air Handling Units (AHU)-09 and AHU-15 in Building 1 of the medical center. The project, estimated between $1,000,000 and $2,000,000, involved comprehensive mechanical system replacement, integration with existing Building Automation Systems, demolition, commissioning, and a one-year warranty. The primary NAICS code was 238220 (Plumbing, Heating, and Air-Conditioning Contractors).
Timeline of Events
The solicitation experienced several amendments. After an initial release, Amendment 0002 paused the process due to a protest challenging the small business set-aside status. Amendment 0003 subsequently resolved the protest, confirming the small business set-aside and establishing new deadlines: a site visit on February 26, 2026, questions due by March 5, 2026, and proposals due by March 16, 2026. Amendment 0004 provided the site visit sign-in sheet.
Cancellation Impact
Amendment 0005, posted on March 18, 2026, formally cancelled the Request for Proposal (RFP) 36C26026R0004 without award. This means no further proposals will be accepted, and the opportunity will not proceed under this solicitation number.
Key Documents Referenced (prior to cancellation)
- Statement of Work (SOW): Detailed the replacement of AHU-09 and AHU-15, including electrical, DDC upgrades, and demolition.
- Drawings: Provided 100% submission drawings for architectural, structural, mechanical, plumbing, and electrical aspects, including phasing and infection control measures.
- Specifications: Outlined technical requirements, safety, site preparation, and asbestos abatement.
- Wage Determination: Specified prevailing wage rates for Spokane County, WA.
- Commissioning Plan: Detailed goals, scope, and team for the commissioning process.
- Risk Assessments (PCRA/ICRA): Highlighted safety, security, environmental, and infection control requirements.
- Limitations on Subcontracting: Required certification for compliance with small business subcontracting rules.
- Past Performance Questionnaire: Outlined requirements for past performance submissions.