FL-PELICAN ISLAND NWR-BUNKHOUSE ROOF

SOL #: 140FC126R0010Combined Synopsis/Solicitation

Overview

Buyer

Interior
Us Fish And Wildlife Service
FWS, CONSTRUCTION A/E TEAM 1
Falls Church, VA, 22041, United States

Place of Performance

Vero Beach, FL

NAICS

Roofing Contractors (238160)

PSC

Repair Or Alteration Of Other Residential Buildings (Z2FZ)

Set Aside

Total Small Business Set-Aside (FAR 19.5) (SBA)

Timeline

1
Posted
Apr 15, 2026
2
Submission Deadline
May 13, 2026, 9:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The U.S. Fish and Wildlife Service (USFWS) is soliciting proposals for a Firm Fixed Price contract to replace the bunkhouse roof at Pelican Island National Wildlife Refuge (NWR) in Vero Beach, FL. The project involves installing a new tin/zinc coated copper double-lock standing seam metal (SSMR) roof. This is a 100% Total Small Business Set-Aside opportunity. Proposals are due May 13, 2026, by 5:00 PM EDT.

Scope of Work

The project requires a complete roof replacement, including the uninstalling and salvaging of the existing rooftop photovoltaic (PV) system, full tear-off of the asphalt shingle roof, inspection for damage, removal and patching of skylights, and installation of a new watertight SSMR assembly. This also includes providing new drainage (gutters, downspouts) and a new lightning protection system. The new SSMR must be copper with tin-zinc coating ("Freedom Gray"), minimum 20 oz, and mechanically-seamed, inverted-L, double-lock standing seam. The building will be unoccupied during construction. Compliance with detailed specifications for materials, installation, and performance standards is mandatory.

Contract & Timeline

  • Contract Type: Firm Fixed Price
  • Set-Aside: Total Small Business (100%)
  • NAICS Code: 238160 - Roofing Contractors
  • Estimated Magnitude: Between $100,000 and $250,000
  • Period of Performance: 365 calendar days after Notice to Proceed
  • Proposal Due: May 13, 2026, 5:00 PM EDT
  • RFIs Due: May 1, 2026, 5:00 PM EDT
  • Site Visit: Highly recommended, appointments accepted April 21-23, 2026.
  • Published Date: April 15, 2026

Eligibility & Requirements

Offerors must be registered in the System for Award Management (SAM) database prior to award. A copy of a State of Florida Certified or Registered Construction Contractor or Roofing Contractor License must be submitted with the proposal. A Bid Guarantee is required, and Performance and Payment Bonds will be necessary. Compliance with Davis-Bacon Wage Rates (General Decision Number FL20260209) is mandatory. Required warranties include a minimum 5-year contractor installation, 50-year/lifetime material, 5-year manufacturer's no-dollar-limit, and 20-year paint finish warranty; warranties exceeding these minimums may be considered competitive.

Evaluation

Award will be made on a Lowest Price Technically Acceptable (LPTA) basis. The successful Quoter's proposal must conform to solicitation requirements, be technically acceptable, and offer the lowest evaluated price.

Submission & Contact

Proposals, including all required documents, must be submitted via email to john_ferrall@fws.gov. The subject line must be "Proposal Submission-140FC126R0010". For site visit appointments, contact Oliver Van Den Ende (oliver_vandenende@fws.gov) or Eric Verderber (eric_verderber@fws.gov). All questions must be submitted in writing via email to John Ferrall.

People

Points of Contact

Ferrall, JohnPRIMARY

Files

Files

Download
Download
Download
Download
Download
Download
Download

Versions

Version 1Viewing
Combined Synopsis/Solicitation
Posted: Apr 15, 2026
FL-PELICAN ISLAND NWR-BUNKHOUSE ROOF | GovScope