TINKER AFB MAC BOA WWYK150083 - Repair Transformer Vault 6, B9001

SOL #: FA813726R0008Pre-Solicitation

Overview

Buyer

DEPT OF DEFENSE
Dept Of The Air Force
FA8137 AFSC PZIOC
TINKER AFB, OK, 73145-9125, United States

Place of Performance

S Coffeyville, OK

NAICS

Commercial and Institutional Building Construction (236220)

PSC

Repair Or Alteration Of Restoration Of Real Property (Public Or Private) (Z2QA)

Set Aside

Total Small Business Set-Aside (FAR 19.5) (SBA)

Timeline

1
Posted
Jan 21, 2026
2
Last Updated
Mar 25, 2026
3
Response Deadline
Mar 25, 2026, 9:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of the Air Force is soliciting proposals from Tinker AFB MAC BOA Holders ONLY for the Repair of Transformer Vault 6, Building 9001 at Tinker Air Force Base, Oklahoma. This project involves the replacement of critical electrical infrastructure. This is a Total Small Business Set-Aside. Proposals are due by April 10, 2026, at 4:00 PM CST.

Scope of Work

The project, designated WWYK150083, requires furnishing all materials, labor, and equipment to repair and replace components within Transformer Vault 6, Building 9001. Key tasks include:

  • Replacement of two gas-filled 2000KVA transformers.
  • Replacement of associated 480V switch gear (labeled #6C and #6D).
  • Replacement of all 15KV switches.
  • Replacement of the original 3000A tie bus.
  • Replacement of interior lighting.
  • Installation of visual fire alarm notification devices to meet ABA requirements.
  • Repair of the vault's exterior.

Key Requirements & Clarifications

  • Eligibility: Only Tinker AFB MAC BOA Holders who attended the mandatory initial site visit on February 5, 2026, are eligible to propose.
  • Transformers: Existing transformers are gas-filled, not oil-filled, and do not require PCB testing or disposal.
  • Busway Transition: Custom busway adapters are intended to extend the existing ITE XL-X busway to the new gear.
  • Metering: Base standard ION8650 meters are expected; externally mounted meters are acceptable if they cannot be mounted to the switchgear.
  • Phasing: Demo work must be phased to minimize production impact, requiring coordination with the user group.
  • Electrical Standards: The project will adhere to the 2025 Tinker AFB electrical standards.
  • Hoist System: Contractors must install and remove their own hoist system; the existing hoist beam is damaged and not to be used.
  • Arc Flash: Arc-flash mitigation techniques shall be used; arc-resistant gear is not suitable due to footprint and lead time.
  • Personnel: Key personnel (Project Manager, Quality Control Manager, Site Safety and Health Officer, Project Superintendent) must meet specific experience requirements. All personnel require AFMC Form 387 badges for base access.
  • Quality Control: Contractor is responsible for a comprehensive inspection system and documentation.
  • Submittals: A detailed Submittal Register outlines all required documentation throughout the project lifecycle.

Contract Details & Timeline

  • Contract Type: Negotiated (RFP)
  • Magnitude: Between $1,000,000 and $5,000,000.
  • Set-Aside: Total Small Business Set-Aside (FAR 19.5).
  • Performance Period: 10 calendar days to commence work after Notice to Proceed (NTP), with 271 calendar days for completion.
  • Liquidated Damages: $277.75 per calendar day for delays.
  • Proposal Due Date: April 10, 2026, at 4:00 PM CST.
  • Additional RFI Questions Due: March 25, 2026, at 4:00 PM CST.
  • Place of Performance: Tinker Air Force Base, Oklahoma (Building 9001, Transformer Vault 6).

Submission & Evaluation

Proposals must be submitted by the deadline. Offerors are instructed to refer to Section L (Instructions to Offerors) and Section M (Evaluation Factors for Award) in the solicitation for specific submission requirements and evaluation criteria. Performance and Payment Bonds are required.

Important Notes

This opportunity is exclusively for Tinker AFB MAC BOA Holders. Attendance at the initial site visit on February 5, 2026, was mandatory for eligibility.

People

Points of Contact

Sara HindsPRIMARY
Megan DonagheSECONDARY

Files

Files

Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download

Versions

Version 10
Pre-Solicitation
Posted: Mar 25, 2026
View
Version 9Viewing
Pre-Solicitation
Posted: Mar 25, 2026
Version 8
Pre-Solicitation
Posted: Mar 24, 2026
View
Version 7
Pre-Solicitation
Posted: Mar 23, 2026
View
Version 6
Pre-Solicitation
Posted: Mar 13, 2026
View
Version 5
Pre-Solicitation
Posted: Mar 12, 2026
View
Version 4
Pre-Solicitation
Posted: Mar 4, 2026
View
Version 3
Pre-Solicitation
Posted: Feb 17, 2026
View
Version 2
Pre-Solicitation
Posted: Feb 2, 2026
View
Version 1
Pre-Solicitation
Posted: Jan 21, 2026
View
TINKER AFB MAC BOA WWYK150083 - Repair Transformer Vault 6, B9001 | GovScope