Z2DA--BLDG 9 SERVER ROOM | 542-26-3-5240-0067 (VA-26-00065869) Split System/Back-Up System

SOL #: 36C24426Q0601Solicitation

Overview

Buyer

Veterans Affairs
Veterans Affairs, Department Of
244-NETWORK CONTRACT OFFICE 4 (36C244)
PITTSBURGH, PA, 15215, United States

Place of Performance

Coatesville,, Pennsylvania

NAICS

Plumbing (238220)

PSC

Repair Or Alteration Of Hospitals And Infirmaries (Z2DA)

Set Aside

Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) (SDVOSBC)

Timeline

1
Posted
May 19, 2026
2
Last Updated
May 19, 2026
3
Submission Deadline
Jun 8, 2026, 2:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of Veterans Affairs (VA), specifically NETWORK CONTRACT OFFICE 4 (36C244), has issued a Solicitation for the installation of a split system/back-up air conditioning system for the Building 9 Server Room at the Coatesville VA Medical Center, Pennsylvania. This opportunity is a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside. Quotes are due by June 4, 2026, at 3:00 PM ET.

Scope of Work

This project requires the installation of two separate air conditioning units:

  • Primary System: One (1) 5-ton Daikin Split System (or equal), including a 5-ton Air Handling Unit, a 5-ton DC6 Condensing Unit (capable of cooling in freezing temperatures), and a Daikin one-touch thermostat (or equal). This includes required electrical connections and ductwork.
  • Secondary (Backup) System: One (1) 4-ton Fujitsu Mini-Split unit (or equal), including wall mounts, a 35-foot line set, communication line with a one-touch thermostat, and wall hangers for the outside condenser unit.

Additional tasks include recovering refrigerant from and removing/discarding the old mini-split unit. The contractor is responsible for verifying site conditions, protecting adjacent structures, adhering to all OSHA and CVAMC safety regulations, checking in with VA Police, and coordinating equipment shutdowns and secure area access with the COR. A minimum one (1) year warranty is required for all services and parts.

Contract Details

  • Contract Type: Firm-Fixed-Price.
  • Period of Performance: 2 weeks, commencing 10 days after the Notice to Proceed.
  • Working Hours: Monday through Friday, 7:00 AM – 4:30 PM.
  • Set-Aside: 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) Concern (NAICS Code: 238220, Small Business Size Standard: $19 million).
  • Project Magnitude: Between $25,000 and $100,000.

Submission & Evaluation

  • Requests for Information (RFIs) Due: June 4, 2026, 4:30 PM ET, via email to Elizabeth.Wilson6@va.gov.
  • Quotes Due: June 4, 2026, 3:00 PM ET, via electronic mail to Elizabeth.Wilson6@va.gov (faxed quotes will not be accepted).
  • Award Basis: Lowest proposed responsive, responsible offeror.
  • Site Visit: A site visit is scheduled for Thursday, May 28, 2026, at 10:00 AM at Building 70, Coatesville VA Medical Center.
  • Compliance: Bidders must return a signed copy of VAAR 852.219-75. The provided Wage Rate Determination for Chester County, Pennsylvania, must be used to ensure compliance with minimum prevailing wages and fringe benefits.

Contact Information

People

Points of Contact

Elizabeth WilsonContracting OfficerPRIMARY

Files

Files

Download
Download

Versions

Version 2Viewing
Solicitation
Posted: May 19, 2026
Version 1
Pre-Solicitation
Posted: May 19, 2026
View
Z2DA--BLDG 9 SERVER ROOM | 542-26-3-5240-0067 (VA-26-00065869) Split System/Back-Up System | GovScope